Curtis liquid level controls with
?
Models LCS/LHS
Two sensitivity ranges for
detection up to 3,000,000 ohms
Features
s Low cost Model LCS for Standard Applications up to 100,000 ohms
s High-Sensitivity Model LHS for Special Applications from 100,000 to
3,000,000 ohms
s Solid-State Amplifier with Potentiometer for Signal Sensitivity
Adjustment
s Positive ON/OFF Operation Eliminates Relay Chatter
s Circuit Limits Short Circuit Probe Current to 10MA/24VAC
s Holding Circuit for Differential Levels, or Manual Reset
s Pre-Wired Auxiliary Contactor Available for Handling Heavy Loads
and Motor Ratings Exceeding Capacity of Plug-In Relay
Specifications
Short Circuit Probe Current : 10MA
Model
Input Supply
Control Relay : Plug-in type with dust cover
Input Supply :
LCS-10/LHS-1
LCS-20/LHS-2
LCS-30
120VAC, 50/60 Hz
240VAC, 50/60 Hz
24VAC, 50/60 Hz.
Probe Contacts : Internally Connected for Holding Circuit
Load Contacts : LCS – SPDT, 1/4 HP, 10 amp Non-inductive, 120VAC 1/3 HP at 240 VAC
LHS – SPDT, 1/6 HP, 10 amp Non-inductive, 120VAC 1/3 HP at 240VAC
Maximum Allowable Supply Voltage Variation : ± 10%
Maximum Power Consumption : 3 Watts
Detectable Range : Up to 100,000 ohms (LCS); Up to 3,000,000 ohms (LHS)
Adjustable Range : 1,000 to 100,000 ohms (LCS); 1,000 to 3,000,000 ohms (LHS)
Operating Point Differential : 3% (Typical)
Signal or Probe Voltage : 24VAC
Maximum Signal or Probe Current : 10MA
Outline and Mounting
Auxiliary Contactor : DPST-NO-DB, rated 1 HP at 120VAC, 2 HP at 240VAC
Ambient Operating Temperature : +32° F to +140° F
Standard Termination : Barrier-type terminal blocks accepting wire up to No.
12AWG. Auxiliary contactor has combination screw/double .250” quick-connects
Mounting Style : Flange
Connection Diagrams
Models LCS/LHS is a forward mode control. The control relay is energized when liquid rises to contact the “H” probe. The control
relay is pulled in and remains energized until liquid drops below the “L” probe. Sensitivity is adjustable.
Ordering
Information
Typical Curtis Model Number
Model (Also refer to “Specifications” above)
LCS-20 - -
Contactor (add “C” if desired)
Enclosure – specify only if necessary –
N3-NEMA 3, N3C–NEMA 3/
Contactor, N4 – NEMA 4 JIC
The composite number above reads as an LCS amplifier for 240VAC supply, without enclosure and without contactor.
For further information on catalog listed controls contact your area Curtis representative or Curtis distributor.
For custom design or modification contact your area Curtis representative or the factory direct.
8
相关PDF资料
LD4006P0 COUNTER 6 DIGIT DUAL 4.0" RED
LD412460 DIODE MOD ISO DUAL 2400V 600A
LIRT220A CONTROL RELAY CURRENT 220VAC
LNXC2000 COUNTER DUAL PRESET 115VAC
LP-56-850 XFRMR 115/230V 28V 1.7A 48VA PCB
LS412460 DIODE MOD ISO SGL 2400V 600A
M4L-3-10 XFRMR 115V 8.7A 1000VA
M5060TB800 MODULE POWER 60A 800V 3PH BRIDGE
相关代理商/技术参数
LCS-10C 制造商:Curtis Industries 功能描述:
LCS-10-C 制造商:Curtis Industries 功能描述:LIQUID LEVEL CONTROL 120V 制造商:Curtis Industries 功能描述:CNTRL LIQ LEVEL 120VAC CHASSIS
LCS-10-C-N3 制造商:Curtis Industries 功能描述:NEMA 3 LIQUID LEVEL CONTROL 120V 制造商:Curtis Industries 功能描述:CNTRL LIQ LEVEL 120VAC CHASSIS
LCS-10-C-N4 制造商:Curtis Industries 功能描述:NEMA 4 JIC LEVEL CONTROL 120V 制造商:Curtis Industries 功能描述:CNTRL LIQ LEVEL 120VAC CHASSIS
LCS-10C-NEMA3 制造商:Curtis Industries 功能描述:
LCS-10-N3 制造商:Curtis Industries 功能描述:NEMA 3 LIQUID LEVEL CONTROL 120V
LCS-10-N4 制造商:Curtis Industries 功能描述:NEMA 4 JIC LEVEL CONTROL 120V 制造商:Curtis Industries 功能描述:CNTRL LIQ LEVEL 120VAC CHASSIS
LCS-10-NEMA3 制造商:Curtis Industries 功能描述: